SIRIUS SI. LOAD FEEDER, 24V DC, S00, SCREW TERMINAL, FC INSTANT.: 3S, 1HL, FC DELAYED: 0S, MC: 0, AUTOSTART / MONITORED START, BASIC UNIT, MAX. ACHIEV. CAT. EN954-1: 4. MAX. ACHIEV. SIL ACC. TO IEC615 RATED POWER: 0.18KW, MOTOR CURRENT: 0.6A, TH. OVERLOAD

Артикул: 3RA7111-0GA17-0AB4
Наименование: SIRIUS SI. LOAD FEEDER, 24V DC, S00, SCREW TERMINAL, FC INSTANT.: 3S, 1HL, FC DELAYED: 0S, MC: 0, AUTOSTART / MONITORED START, BASIC UNIT, MAX. ACHIEV. CAT. EN954-1: 4. MAX. ACHIEV. SIL ACC. TO IEC615 RATED POWER: 0.18KW, MOTOR CURRENT: 0.6A, TH. OVERLOAD COMP.:0.45..0.63A, (siemens)
Производитель: Siemens


Наименование продукта
SIRIUS SI. LOAD FEEDER, 24V DC, S00, SCREW TERMINAL, FC INSTANT.: 3S, 1HL, FC DELAYED: 0S, MC: 0, AUTOSTART / MONITORED START, BASIC UNIT, MAX. ACHIEV. CAT. EN954-1: 4. MAX. ACHIEV. SIL ACC. TO IEC615 RATED POWER: 0.18KW, MOTOR CURRENT: 0.6A, TH. OVERLOAD COMP.:0.45..0.63A,
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2001-01-01 2009-05-15 2009-09-30 2009-09-30
    Версия от 2012-02-25
 
SIRIUS SI. LOAD FEEDER, 24V DC, S00, SCREW TERMINAL, FC INSTANT.: 3S, 1HL, FC DELAYED: 0S, MC: 0, AUTOSTART / MONITORED START, BASIC UNIT, MAX. ACHIEV. CAT. EN954-1: 4. MAX. ACHIEV. SIL ACC. TO IEC615 RATED POWER: 0.18KW, MOTOR CURRENT: 0.6A, TH. OVERLOAD COMP.:0.45..0.63A,
 
General technical details:
Design of the product   direct starter
Operating current / at 400 V / for AC    
  • rated value
A 0.6
Breaking capacity current / at AC-3 A 0.6
Breaking capacity limit short-circuit current (lcu) / at 400 V    
  • rated value
kA 50
Adjustable response current    
  • of the current-dependent overload release
A 0.45 0.63
type of voltage   DC
Supply voltage frequency / for auxiliary and control current circuit    
  • rated value
Hz 0 0
Operating voltage / rated value V 400
Control supply voltage    
  • for DC / rated value
V 24 24
Service power / at AC-3 / at 400 V    
  • rated value
kW 0.18
Type of assignement   2
Item designation    
  • according to DIN EN 61346-2
  A
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
  Q
 
Mechanical design:
Type of the safety-related wiring    
  • 1-channel
  Yes
  • 2-channel
  Yes
Design of the electrical connection    
  • for main current circuit
  screw-type terminals
Design of the cascading   yes
Size of the load feeder   S00
Width mm 90
Height mm 211
Depth mm 113
Product function    
  • monitored start-up
  Yes
  • automatic start
  Yes
  • emergency stop function
  Yes
  • short circuit protection
  Yes
  • bus-communication
  No
Suitability for interaction / pressing control   No
 
Protocols:
 
Protocol / will be supported    
  • AS interface protocol
  No
  • PROFIBUS DP protocol
  No
 
Certificates/approvals:
   
General Product Approval Functional Safety / Safety of Machinery other
ROSTEST
 
 
last change:
Feb 6, 2012


Назад в раздел