SINVERT PVM17 INVERTER FOR PV, GRID CONNECT. LV, IEC 50/60HZ, 3P, 400VAC, STANDARD MPP, UMAX 1000VDC, 4 DC-INPUTS, IP65, AIR COOLING, SINVERT PVM WARRANTY - 5 YEARS |
|
General technical data: |
product brand name | | SINVERT |
Product-type designation | | SINVERT PVM17 |
product designation | | photovoltaic inverter |
Output class for PV inverters | | 17 |
Design of PV inverter unit | | single device |
Number of PV inverter sub-units | | 1 |
Type of installation | | indoor installation / outdoor installation |
Protection class IP | | IP65 |
Operating resource protection class | | I |
Installation altitude / at rated value of power / at a height above sea level / maximum | m | 2,000 |
Incoming air temperature / at nominal value of active power supplied / maximum | °C | 45 |
Ambient temperature | | |
| °C | -25… +55 |
| °C | -25… +70 |
| °C | -25… +70 |
Relative humidity / without condensation | | |
| % | 4… 100 |
Climatic class | | 4K4H |
Type of cooling | | natural convection |
A-rated sound power level / maximum | dB | 45 |
RAL color number | | RAL 7035 |
Design of the display | | graphical (with backlight) |
Horizontal image resolution | | 128 |
Vertical screen resolution | | 64 |
Number of colors / of the display | | 2 |
Design of the display / touchscreen | | No |
Design of the control elements | | 8 membrane keys |
National language / at the indicator of the display / selectable | | English, French, German, Italian, Spanish, Czech |
Design of the interface / for communication | | Ethernet, RS485 |
Product feature / functional earth | | No |
Connection method for PV inverters | | without transformer |
Product function / galvanic isolation | | No |
Product component | | |
- input for radiation sensor
| | Yes |
- relay output for fault message
| | Yes |
|
Inputs: | | |
MPP voltage | V | 525… 850 |
Input voltage / on the DC side | | |
- for the start of the infeed operation
| V | 350 |
- for possible infeed operation
| V | 350… 950 |
| V | 600 |
| V | 1,000 |
Consumed active power / on the DC side / nominal value | W | 16,800 |
Total power used / on the DC side / maximum | A | 32 |
Number of inputs / on the DC side | | 4 |
Input current / per DC input / maximum | A | 25 |
Product component / on the DC side | | |
| | Yes |
| | Yes |
Design of the overvoltage protection / on the DC side | | type 3 |
|
Outputs: | | |
Phase number | | 3 |
Output voltage / on the AC side / for infeed operation / nominal value | V | 400 |
Output voltage / on the AC side | | |
| V | 320… 480 |
Line frequency | | |
| | |
- for infeed operation / nominal value
| Hz | 50 |
| | |
- for infeed operation / nominal value
| Hz | 60 |
Active power supplied / on the AC side | | |
- in permanent operation / nominal value
| W | 16,500 |
| W | 16,500 |
Current supplied / on the AC side / maximum | A | 25 |
Power factor / at nominal value of active power supplied / nominal value | | 1 |
Power factor inductive / minimum | | 0.9 |
Power factor capacitive / minimum | | 0.9 |
Relative residual ripple / of AC current / at nominal value of the AC active power / on unloaded line / maximum | % | 2.5 |
Grounding concept / on the AC side | | TN-S |
Design of protection / on the AC side / required | | 32 (type B) |
Product component / on the AC side / overvoltage protection | | Yes |
Design of the overvoltage protection / on the AC side | | type 3 |
|
Efficiency / heat loss: | | |
Efficiency / maximum possible | % | 98 |
Euro efficiency | % | 97.7 |
Apparent power consumed | | |
- in night-time operating mode
| V·A | 0.5 |
- in standby operating mode
| V·A | 0.5 |
Input power / on the DC side / for possible infeed operation / minimum | W | 60 |
|
Connections: | | |
Design of the electrical connection | | |
| | MC4 |
| | connector |
Conductor cross-section that can be connected / at the AC- output / stranded wire | | |
- with conductor end processing
| mm² | 4… 6 |
Lockable cable diameter |
|