SIMATIC DP, ELECTRONIC MODULE FOR ET 200S, 2 PULSE PULSED GENERATOR AND TIMER MODULE, 15 MM WIDE, 2 CHANNELS

Артикул: 6ES7138-4DD01-0AB0
Наименование: SIMATIC DP, ELECTRONIC MODULE FOR ET 200S, 2 PULSE PULSED GENERATOR AND TIMER MODULE, 15 MM WIDE, 2 CHANNELS (siemens)
Производитель: Siemens


Наименование продукта
SIMATIC DP, ELECTRONIC MODULE FOR ET 200S, 2 PULSE PULSED GENERATOR AND TIMER MODULE, 15 MM WIDE, 2 CHANNELS
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2001-03-30 2010-10-01 2010-10-01
Manuals weitere>>
Technological Functions ET 200S  2005-07-14
SIMATIC DP, ELECTRONIC MODULE FOR ET 200S, 2 PULSE PULSED GENERATOR AND TIMER MODULE, 15 MM WIDE, 2 CHANNELS
Supply voltage
Load voltage L+
Rated value (DC) 24 V; From power module
Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 40 mA
from backplane bus 3.3 V DC, max. 10 mA
Encoder supply
Output voltage L+ (-0.8 V)
Output current, rated value 500 mA
Output current
Short-circuit protection Yes
Power losses
Power loss, typ. 1.8 W
Digital inputs
Number/binary inputs 2
Input characteristic curve acc. to IEC 61131, Type 2 Yes
Input voltage
Rated value, DC 24 V
for signal "0" -30 to +5 V
for signal "1" 11 to 30 V
Input current
for signal "1", typ. 9 mA
Input delay (for rated value of input voltage)
Input frequency (with a time delay of 0.1 ms), max. 20 kHz
Minimum pulse width for program reactions 100 µs
Cable length
Cable length, shielded, max. 100 m
Digital outputs
Number/binary outputs 2
Functionality/short-circuit strength Yes
Response threshold, typ. 10 A
Limitation of inductive shutdown voltage to L+ (-50 to -65 V)
Lamp load, max. 10 W
Accuracy of pulse duration +/- (pulse duration x 100 ppm) , +/-100 µs with a load <= 50 ohms
minimum pulse duration 200 µs
Controlling a digital input Yes
Output voltage
for signal "1", min. L+ (-1 V)
Output current
for signal "1" rated value 2 A
for signal "1" permissible range for 0 to 60 °C, min. 7 mA
for signal "1" permissible range for 0 to 60 °C, max. 2 A
for signal "0" residual current, max. 0.5 mA
Output delay with resistive load
0 to "1", max. 100 µs
1 to "0", max. 200 µs
Switching frequency
with resistive load, max. 2.5 kHz
with inductive load, max. 2 Hz
on lamp load, max. 10 Hz
Cable length
Cable length, shielded, max. 1000 m
Cable length unshielded, max. 600 m
Encoder
Connectable encoders
2-wire sensor Yes
Permissible quiescent current (2-wire sensor), max. 2 mA
Interrupts/diagnostics/status information
Diagnostics indication LED
Group error SF (red) Yes
Status indicator digital output (green) Yes
Status indicator digital input (green) Yes
Pulse generator
Number of channels 2; 1 digital input and 1 digital output per channel
Galvanic isolation
Galvanic isolation digital inputs
between the channels No
between the channels and the backplane bus Yes
Galvanic isolation digital outputs
between the channels No
between the channels and the backplane bus Yes
Permissible potential difference
between different circuits 75 VDC / 60 VAC
Isolation
Isolation checked with 500 V DC
Dimensions
Width 15 mm
Height 81 mm
Depth 52 mm
Weight
Weight, approx. 40 g