SIMATIC WINAC RTX 2008, SINGLE LICENSE F. 1 INSTALL., R-SW, SW AND DOCU. ON DVD, LICENSE KEY ON USB STICK, CLASS A, 3 LANGUAGES (D,E,F), EXECUTABLE UNDER WIN XP SP2 AND ARDENCE RTX, REFERENCE-HW: SIMATIC PC
Артикул: 6ES7671-0RC06-0YA0
Наименование: SIMATIC WINAC RTX 2008, SINGLE LICENSE F. 1 INSTALL., R-SW, SW AND DOCU. ON DVD, LICENSE KEY ON USB STICK, CLASS A, 3 LANGUAGES (D,E,F), EXECUTABLE UNDER WIN XP SP2 AND ARDENCE RTX, REFERENCE-HW: SIMATIC PC (siemens)
Производитель: Siemens
|
|
| Наименование продукта SIMATIC WINAC RTX 2008, SINGLE LICENSE F. 1 INSTALL., R-SW, SW AND DOCU. ON DVD, LICENSE KEY ON USB STICK, CLASS A, 3 LANGUAGES (D,E,F), EXECUTABLE UNDER WIN XP SP2 AND ARDENCE RTX, REFERENCE-HW: SIMATIC PC | | Версия от 2012-03-10 | | | SIMATIC WINAC RTX 2008, SINGLE LICENSE F. 1 INSTALL., R-SW, SW AND DOCU. ON DVD, LICENSE KEY ON USB STICK, CLASS A, 3 LANGUAGES (D,E,F), EXECUTABLE UNDER WIN XP SP2 AND ARDENCE RTX, REFERENCE-HW: SIMATIC PC | | General information | Hardware product version | - | Firmware version | 4,4 | Engineering with | Programming package | STEP7 V5.4 SP4 or higher + HW update / iMap V3.0 SP1 | Memory | Work memory | integrated | PC RAM can be used (non-paged memory) | Load memory | integrated RAM, max. | PC RAM can be used (non-paged memory) | CPU processing times | for bit operations, min. | 0.0040 µs; typ. | for fixed point arithmetic, min. | 0.0030 µs; typ. | for floating point arithmetic, min. | 0.0040 µs; typ. | Reference platform | Pentium IV, 2.4 GHz | CPU-blocks | DB | Number, max. | Limited only by available PC work memory | Size, max. | 64 kbyte | FB | Number, max. | Limited only by available PC work memory | Size, max. | 64 kbyte | FC | Number, max. | Limited only by available PC work memory | Size, max. | 64 kbyte | OB | Number, max. | Limited only by available PC work memory | Size, max. | 64 kbyte | Number of free cycle OBs | 1; OB 1 | Number of time alarm OBs | 1; OB 10 | Number of delay alarm OBs | 1; OB 20 | Number of time interrupt OBs | 9; OB 30-38 | Number of process alarm OBs | 1; OB 40 | Number of ODK OBs | 3; OB 52-54 | Number of DPV1 alarm OBs | 3; OB 55-57 | Number isochronous mode OBs | 2; OB 61-62 | Number of startup OBs | 2; OB 100, 102 | Number of asynchronous error OBs | 7; OB 80, 82-85, 86, 88 | Number of synchronous error OBs | 2; OB 121, 122 | Nesting depth | per priority class | 24 | additional within an error OB | 24 | Counters, timers and their retentivity | S7 counter | Number | 2048 | Retentivity | adjustable | Yes | lower limit | 0 | upper limit | 2047 | preset | 8 | Counting range | adjustable | Yes | lower limit | 0 | upper limit | 999 | IEC counter | present | Yes | Type | SFB | S7 times | Number | 2048 | Retentivity | adjustable | Yes | lower limit | 0 | upper limit | 2047 | preset | 0 | Time range | lower limit | 10 ms | upper limit | 9990 s | IEC timer | present | Yes | Type | SFB | Data areas and their retentivity | Retentivity without UPS and PS Extension Board | 128 KB with SIMATIC Microbox PC 427B and Panel PC 477B; other SIMATIC PCs on request | Retentivity with UPS | all data | Flag | Number, max. | 16 kbyte | of which retentive | MB 0 to MB 16383 | Retentivity preset | MB 0 to MB 15 | Number of clock memories | 8 | Address area | I/O address area | Inputs | 16 kbyte | Outputs | 16 kbyte | of which, distributed | DP interface, inputs | 16 kbyte | DP interface, outputs | 16 kbyte | PN interface, inputs | 16 kbyte | PN interface, outputs | 16 kbyte | Process image | Inputs, adjustable | 8 kbyte | Outputs, adjustable | 8 kbyte | Inputs, default | 512 byte | Outputs, default | 512 byte | Subprocess images | Number of subprocess images, max. | 15 | Digital channels | Inputs | 128000 | Outputs | 128000 | Analog channels | Inputs | 8000 | Outputs | 8000 | Hardware configuration | Submodules | Number of submodules, max | 4 | of which PROFIBUS, max. | 4; CP 5611, CP 5611-A2, integrated PB interface of the SIMATIC PC, CP 5613 CP, 5613-A2, CP 5603 | of which Industrial Ethernet, max. | 1; PROFINET: CP1616, CP1604, S7-mEC integrated PN interface and SIMATIC PC | Number of operable FMs and CPs (recommended) | FM | 4; FM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2 | CP, point-to-point | 2; CP 340, CP 341 distributed | CP, LAN | Over PC CP | Time of day | Clock | Hardware clock (real-time clock) | Yes | battery-backed and synchronizable | Yes | Clock synchronization | supported | Yes | t
|
Назад в раздел
|
| |