BCL 90 CAT F 100 H - Stationary barcode reader
Àðòèêóë: 50035512
Íàèìåíîâàíèå: BCL 90 CAT F 100 H - Stationary barcode reader
Ïðîèçâîäèòåëü: Leuze electronic
|
|
Part description | BCL 90 CAT F 100 H - Stationary barcode reader | Part no. | 50035512 | -
Basic data -
Read data - Code types, readable2/5 Interleaved, Code 39, Code 128, Code 93, Codabar, EAN 8/13, EAN 128, UPC
- Scanning rate, typical800 scans/s
-
Optics - Reading distance500 ... 2.200 mm
- Light sourcelaser, Red
- Laser light wavelength650 nm
- Laser safety class2, EN 60825
- Reading methodLine scanner
- Scanning rate600 ... 1.200 scans/s
- Beam deflectionBy means of rotating polygon wheel
- Light beam exitHead
-
Electrical equipment -
Performance data - Supply voltage24 V, DC, -10 ... 20 %
- Power consumption, max.90 V·A
-
Inputs - Number of digital switching inputs6 Piece(s)
-
Outputs - Number of digital switching outputs4 Piece(s)
-
Interface - TypeRS 232, RS 422, RS 485
-
RS 232 -
RS 422 -
RS 485 -
Service interface - TypeRS 232
-
RS 232 - FunctionConfiguration via software
-
Connection - Number of connections2 Piece(s)
-
Connection 1 - Type of connectionSub-HD
- FunctionVoltage supply, Service interface, Data interface
- No. of pins15 Piece(s)
- ModelMale
- Designation on deviceHost / Term
-
Connection 2 - Type of connectionSub-HD
- Designation on deviceI/O
- FunctionSignal IN, Signal OUT, Voltage supply
- No. of pins15 Piece(s)
- ModelFemale
-
Mechanical data - DesignCube
- Dimension117 mm x 94 mm x 117 mm
- Housing materialMetal, aluminum
- Lens cover materialGlass
- Net weight1.500 g
- Housing colorRed, RAL 3000, Black, RAL 9005
- Type of fasteningMounting thread, Via optional mounting device
-
Operation and display - Type of displayLED
- Number of LEDs4 Piece(s)
- Type of configurationSoftware
- Operational controlsPC software
-
Environmental data - Ambient temperature, operation-35 ... 35 °C
- Ambient temperature, storage-20 ... 70 °C
- Relative humidity (non-condensing)90 %
-
Certifications - Protection classIP 65
- Safety classIII
- CertificationsCE
- Test procedure for EMC in accordance with standardIEC 801
- Test procedure for shock in accordance with standardIEC 60068-2-27, test Ea
- Test procedure for vibration in accordance with standardIEC 68.2.6
-
Functions - FunctionsCode fragment technology, Alignment mode, LED indicators, Heating, Reference code comparison
Part data of: 2013-11-24 21:03:00
|