Number of safe inputs12 Piece(s), (up to SIL 3 / IEC 62061) of which 4 are configurable as input or output
Status display1 LED (green) per input
Nominal voltage UN24 VÂ DC
Typ. current consumption at UN4 mA
Signal level at 0, max.5 V
Signal level at 1, min.11 V
Outputs
Number of safe semiconductor outputs4 Piece(s), (Cat. 4 / EN ISO 13849-1 / EN 954) for configuration of the 4 inputs/outputs as outputs
Number of clock/signal outputs2 Piece(s), Can be used as pulse output or signal output depending on configuration
Output data
Nominal voltage24 V DC, -15 ... 10 %
Status display1 LED (green) per output
Limiting continuous current0.5 A
Clock outputs
Nominal voltage24 VÂ DC
Limiting continuous current50 mA
Signal outputs
Nominal voltage24 VÂ DC
Limiting continuous current50 mA
Connection
Number of connections2 Piece(s)
Connection 1
Type of connectionTerminal
FunctionVoltage supply, Signal IN, Signal OUT, Connection to device
Type of terminalSpring-cage terminal
No. of pins16 Piece(s)
Connection 2
Type of connectionTBUS DIN rail
FunctionInternal communication interface
Cable properties
Connection cross-sections0.2 to 1.5 mm²
Mechanical data
Dimension22.5 mm x 114.5 mm x 112 mm
Housing materialplastic, Unreinforced polyamide PA
Net weight180 g
Housing colorgray
Type of fasteningSnap-on mounting
Environmental data
Ambient temperature, operation-5 ... 45 °C
Ambient temperature, storage-20 ... 70 °C
Certifications
Protection classIP 20 (housing), IP 20 (terminals)
CertificationsCE, c UL US, TÃœV Rheinland
Functions
FunctionsMonitoring of all safe functions in machines and systems, Extension module for the MSI 200 programmable safety controller, Extension with 8 safe inputs and 4 safe, freely configurable channels-either as safe inputs or outputs (OSSDs)