S400-M4M12-B - Safety hinge switch

Àðòèêóë: 63000401
Íàèìåíîâàíèå: S400-M4M12-B - Safety hinge switch
Ïðîèçâîäèòåëü: Leuze electronic


Part description S400-M4M12-B - Safety hinge switch
Part no. 63000401



  • Technical features

    • Basic data
      • SeriesS400
    • Characteristic parameters
      • Service life20 years, EN ISO 13849-1
      • Mechanical life time1.000.000 actuation cycles, IEC 6047-5-1
      • B10d2.000.000 number of cycles
      • Usage category at DC 13Ue 24 V, Ie 2 A, EN 60947-5-1
      • Usage category at AC 15Ue 24 V, Ie 2 A, EN 60947-5-1
    • Electrical equipment
      • Contact equipment2NC + 1NO
      • Contact openingForce-fit
      • Short circuit protected500 V, 2 A, type gG, IEC 60269-1
      • Performance data
        • Rated insulation voltage30 V AC, 36 V DC
        • Conventional thermal current, max.2 A
    • Connection
      • Number of connections1 Piece(s)
      • Connection 1
        • Type of connectionConnector
        • FunctionContact connection
        • Thread sizeM12
        • MaterialMetal
        • No. of pins8 Piece(s)
    • Mechanical data
      • DesignCube
      • Dimension49 mm x 22.5 mm x 100.6 mm
      • Housing materialMetal, ZAMAK
      • Electrical contact materialSilver alloy
      • Net weight300 g
      • Housing colorSilver
      • Type of fasteningMounting thread, Mounting plate
      • Side of cable entryFrom below (with left installation)
      • Switch typeInterlock device without guard interlocking, EN 1088
      • Switching principleCreep contact
      • Axial stress1.500 N·m
      • Radial stress1.000 N·m
      • Torsional stress25 N·m
      • Actuation frequency, max.1.200 per hour, IEC 6047-5-1
      • Internal actuatorSafety switch in hinge, encapsulated
      • Actuating path (angle) with forced separation4 N, From set switching point
      • Actuation angle, max.180 °
    • Environmental data
      • Ambient temperature, operation-25 ... 80 °C
    • Certifications
      • Protection classIP 67, IP 69K
      • CertificationsIMQ, c UL US, CE
      • Degree of contamination3, EN 60947-1
    • Functions
      • FunctionsLocking device without guard interlocking in acc. with EN 1088, Integration in control circuits up to category 4 in accordance with EN ISO 13849, Mechanical hinge with integrated safety switch
  • Downloads

  • Part data of: 2013-11-24 21:03:00



    Íàçàä â ðàçäåë