AS-Interface safety module | VAA-2E-G4-SN

Артикул: VAA-2E-G4-SN
Наименование: AS-Interface safety module | VAA-2E-G4-SN
Производитель: Pepperl-Fuchs


Not available for purchase, If you need assistance please contact us sales@quad-industry.com
Оборудование снято с производства, для уточнения замены свяжитесь с нами sales@quad-industry.com

  • Two inputs for SN sensors or two mechanical contacts such as EMERGENCY-STOP switch
  • Protection degree IP67
  • Flat or round cable connection (via standardized EMS base, not included with delivery)
  • Cross-circuit detection for mechanical switches

Datasheet as PDF in following languages:


Technical Data: VAA-2E-G4-SN

Product Description
G4 PG module IP67
safety module with 2 inputs
General specifications
Slave typeSafety-Slave
AS-Interface specificationV2.1
Required master specification≥ V2.0
UL File NumberE87056
Indicators/operating means
LED FAULTerror display; LED red
red: communication error or address is 0
LED PWRAS-Interface voltage; LED green
LED INswitching state (input); 2 LED yellow
Electrical specifications
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 70 mA
Protection classIII
Fault currentmax. 90 mA
Input
Number/Type2 Inputs for SN sensors (category S, EN 60947-5-3; category 3+4, EN 954-1) or for mechanical contacts (category 4, EN 954-1) Inputs for mech. switch, monitored for cross-circuit, cable length < 30 m
Supplyfrom AS-Interface
Current loading capacityinput current limited ≤ 15 mA,
overload and short-circuit resistant
Switching pointSN specification
mech. switch current 10 mA pulsed
Programming instructions
ProfileS-0.B
IO code0
ID codeB
ID1 codeF
ID2 codeE
Data bits (function via AS-Interface) input output
D0 dyn. safety code 1 -
D1 dyn. safety code 1 -
D2 dyn. safety code 2 -
D3 dyn. safety code 2 -
Parameter bits (programmable via AS-i)function
P0not used
P1not used
P2not used
P3not used
Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 61000-6-4:2007, EN 50295:1999
Standard conformity
Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-4-x, EN 61000-4-5:2005 1kV asymmetric, criterion B, EN 61000-6-4:2007, EN 55011:2009
Emitted interferenceEN 61000-6-4:2001
Insulation coordinationEN 50178:1998
Functional safetyDIN EN 954-1:1996 (by category 4) , IEC 60947-5-3:1999
Protection degreeEN 60529:2000
Fieldbus standardEN 50295:1999, IEC 62026-2:2006
Electrical safetyIEC 60204-1:2007
Ambient conditions
Ambient temperature-25 ... 55 В°C (-13 ... 131 В°F)
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Relative humidity< 95 %
Mechanical specifications
Protection degreeIP67
Connectioncable piercing method or terminal compartment
yellow flat cable or standard round cable
inputs: M12 x 1.5 cable gland and cage tension spring terminals
Material
HousingPA 6 GF30
Mass180 g
MountingDIN rail or screw mounting


Назад в раздел