3VL3

3VL31202KN300AA0 MOLDED CASE CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; FG FRAME; 240/480/600 VAC AT 50/60 HZ, 250/500 VDC (UL); 240/415/690 VAC AT 50/60 HZ, 250 VDC (IEC); 200 AMPERE AT 40 DEG C; 3 POLE _ Siemens
3VL31252GE300AA0 MOLDED CASE CIRCUIT BREAKER, SOLID STATE, MOLDED CASE; FG FRAME; 240/480/600 VAC AT 50/60 HZ, 250/500 VDC (UL); 240/415/690 VAC AT 50/60 HZ, 250 VDC (IEC); 250 AMPERE AT 40 DEG C; 3 POLE _ Siemens
3VL31252GB300AA0 MOLDED CASE CIRCUIT BREAKER, SOLID STATE, MOLDED CASE; FG FRAME; 240/480/600 VAC AT 50/60 HZ, 250/500 VDC (UL); 240/415/690 VAC AT 50/60 HZ, 250 VDC (IEC); 250 AMPERE AT 40 DEG C; 3 POLE _ Siemens
3VL31202KN300AA0 MOLDED CASE CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; FG FRAME; 240/480/600 VAC AT 50/60 HZ, 250/500 VDC (UL); 240/415/690 VAC AT 50/60 HZ, 250 VDC (IEC); 200 AMPERE AT 40 DEG C; 3 POLE _ Siemens
3VL3725-3TH43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3TF43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3TE43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3SB33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3TN46-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3TN46-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-3TN43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3TN43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-3TH46-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3TH46-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-3NH43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3TH43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-3SS33-0A.. . VL 250L . ... R.U.S.-C.BR.C.= 100 KA, 415V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3SH33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3SS36-.... . VL 250L . ... R.U.S.-C.BR.C.= 100 KA, 415V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION SIEMENS
3VL3725-3MS33-0A.. . VL 250L . ... R.U.S.-C.BR.C.= 100 KA, 415V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3SS33-.... . VL 250L . ... R.U.S.-C.BR.C.= 100 KA, 415V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITH SIEMENS
3VL3725-3SP36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3SP36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3725-3SP33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3SP33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3725-3SH36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3SH36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3725-3MH33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3SH33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-3SG36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3MG33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3SE36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3725-3SE33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3NB43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-3MS36-0A.. . VL 250L . ... R.U.S.-C.BR.C.= 100 KA, 415V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3MG36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3725-3SG33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3MG33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-3SL36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3SL36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3725-3SL33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3SL33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3725-3ME36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3SE33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-3SB36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3SB36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3725-3MB33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3SB33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3725-3LS36-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LS36-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LS33-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LS33-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LF46-0A.. . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LF46-.... . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LF43-0A.. . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LF43-.... . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LE36-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LE36-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LE33-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LE33-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LB36-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LB36-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LB33-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LB33-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LA46-0A.. . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LA46-.... . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LA43-0A.. . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3LA43-.... . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-3EM46-.... . VL 250L . . ICU= 100KA, 415V AC 4 , .. TM, LI IN= 250A, . IR= 200...250A, II= 1250...2500A, .. N (100%) SIEMENS
3VL3725-3EM43-.... . VL 250L . ... ICU= 100KA, 415V AC 4 ., LINE PROTECTION TM, LI IN= 250A, RATED CURRENT IR= 200...250A, OVERLOAD II= 1250...2500A, SHORT-CIRCUIT N PROTECTED (100%) WITH SIEMENS
3VL3725-3EJ46-.... VL 250L ICU=100KA/415 V AC 4-, , TM, LI IN=250A, IR=200-250A, II=1200-2500A, SIEMENS
3VL3725-3EJ43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500A, SHORT-CIRCUIT N NOT PROTECTED WITH SIEMENS
3VL3725-3EE46-.... VL 250L ICU=100KA/415 V AC 4-, IN=250A, II=4000A, .. SIEMENS
3VL3725-3EE43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., NON-AUTOMATIC MAGNETIC IN=250A, RATED CURRENT II=3500A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-3EC46-.... VL 250L ICU=100KA/415 V AC 4-, , TM, LI IN=250A, IR=200-250A, II=1200-2500A, SIEMENS
3VL3725-3EC43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500A, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-3DK36-.... VL 250L ICU=100KA/415 V AC 3-, IN=250A, II=2000-4000A, .. SIEMENS
3VL3725-3DK33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., STARTER COMBINATION PROTECTION MAGNETIC IN=250A, RATED CURRENT II=2000-4000A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-3DE36-.... VL 250L ICU=100KA/415 V AC 3-, IN=250A, II=4000A, .. SIEMENS
3VL3725-3DE33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., NON-AUTOMATIC MAGNETIC IN=250A, RATED CURRENT II=3500A, SHORT-CIRCUIT II=4000A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-3DC36-.... VL 250L ICU=100KA/415 V AC 3-, , TM, LI IN=250A, IR=200-250A, II=1200-2500A, .. SIEMENS
3VL3725-3DC33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-3CP36-0A.. . VL 250L . . ICU=100KA / 415 V AC 3 , MOTOR/GENERATOR PROTECTION .. LCD ETU40M, LI IN=250A, . IR=100-250A, II=1,25TO11XIN, .. . SIEMENS
3VL3725-3CP36-.... VL 250L ICU=100KA/415 V AC 3-, ./ .. LCD ETU40M, LI IN=250A, IR=0,4.1,0 X IN, II=1,25 11XIN, .. SIEMENS
3VL3725-3CP33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3CP33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITH SIEMENS
3VL3725-3CN46-0A.. . VL 250L . . ICU=100KA / 415 V AC 4 , .. LCD ETU42, LSIG IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. N .. WITHOUT SIEMENS
3VL3725-3CN46-.... VL 250L ICU=100KA/415 V AC 4-, , LCD ETU42, LSIG IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3725-3CN43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3CN43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITH SIEMENS
3VL3725-3CM36-0A.. . VL 250L . . ICU=100KA / 415 V AC 3 , .. LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. WITHOUT A SIEMENS
3VL3725-3CM36-.... VL 250L ICU=100KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=250A, IR=100-250A, ISD=1,5 10XIR, II=1 SIEMENS
3VL3725-3CM33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3CM33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-3CL36-0A.. . VL 250L . . ICU=100KA / 415 V AC 3 , .. LCD ETU42, LSIG 3/3 IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. WITHOUT AUXILIARY RELE SIEMENS
3VL3725-3CL36-.... VL 250L ICU=100KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=250A, IR=100-250A, ISD=1,5 10XIR, II=1 SIEMENS
3VL3725-3CL33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3CL33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-3CJ46-0A.. . VL 250L . . ICU=100KA / 415 V AC 4 , .. LCD ETU40, LI/LS/LSI IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. N WITHOUT AUXILIARY RE SIEMENS
3VL3725-3CJ46-.... VL 250L ICU=100KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3725-3CJ43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3CJ43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-3CH36-0A.. . VL 250L . . ICU=100KA / 415 V AC 3 , .. LCD ETU40, LI/LS/LSI IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. . SIEMENS
3VL3725-3CH36-.... VL 250L ICU=100KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL3725-3CH33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3CH33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-3AA46-0AA0 . VL 250L . ... ICU= 100 KA / 415 V AC, 4- IN= < 250 A, RATED CURRENT WITHOUT AUXILIARY RELEASE WITH SCREW CONNECTIONS CONTACT UNIT AND OVERVOLTAGE RELEASE SIEMENS
3VL3725-3AA36-0AA0 . VL 250L . ... ICU= 100 KA / 415 V AC, 3- IN= < 250 A, RATED CURRENT WITHOUT AUXILIARY RELEASE WITH SCREW CONNECTIONS CONTACT UNIT AND OVERVOLTAGE RELEASE SIEMENS
3VL3725-2SS33-0A.. . VL 250H ... R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3NF43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3TF46-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3TF46-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-3NE43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-3TF43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-3TB46-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-3NA46-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-3NA43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2SH33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2TN46-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2TN46-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-2TN43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2TN43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-2TH46-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2TH46-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-2TH43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2TH43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-2TF46-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2TF46-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-2TF43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2TF43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-2TB46-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2TB46-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-2TB43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2TB43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-2SS36-0A.. . VL 250H ... R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2SS36-.... . VL 250H ... R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION SIEMENS
3VL3725-2MS33-0A.. . VL 250H ... R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2SS33-.... . VL 250H ... R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITH SIEMENS
3VL3725-2SP36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2SG36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3725-2SG33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2SG33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-2SE33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-2SB36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2SB36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3725-2SB33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2SB33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3725-2LS36-0A.. . VL 250H ... ICU= 70KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LS36-.... . VL 250H ... ICU= 70KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LS33-0A.. . VL 250H ... ICU= 70KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LS33-.... . VL 250H ... ICU= 70KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LF46-0A.. . VL 250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 XIR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LF46-.... . VL 250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 XIR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LF43-0A.. . VL 250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 XIR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LF43-.... . VL 250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 XIR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LE36-0A.. . VL 250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LE36-.... . VL 250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LE33-0A.. . VL 250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LE33-.... . VL 250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LB36-0A.. . VL 250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LB36-.... . VL 250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LB33-0A.. . VL 250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LB33-.... . VL 250H ... ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LA46-0A.. . VL 250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LA46-.... . VL 250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LA43-0A.. . VL 250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2LA43-.... . VL 250H ... ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-2EM46-.... . VL 250H . ICU= 70KA, 415V AC 4 , .. TM, LI IN= 250A, . IR= 200...250A, II= 1250...2500A, .. N (100%) SIEMENS
3VL3725-2EM43-.... . VL 250H ... ICU= 70KA, 415V AC 4 ., LINE PROTECTION TM, LI IN= 250A, RATED CURRENT IR= 200...250A, OVERLOAD II= 1250...2500A, SHORT-CIRCUIT N PROTECTED (100%) WITH SIEMENS
3VL3725-2EJ46-.... VL 250 H ICU=70KA/415 V AC 4-, , TM, LI IN=250A, IR=200-250A, II=1200-2500A, SIEMENS
3VL3725-2EJ43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500A, SHORT-CIRCUIT N NOT PROTECTED WITH SIEMENS
3VL3725-2EE46-.... VL 250 H ICU=70KA/415 V AC 4-, IN=250A, II=4000A, .. SIEMENS
3VL3725-2EE43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., NON-AUTOMATIC MAGNETIC IN=250A, RATED CURRENT II=3500A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-2EC46-.... VL 250 H ICU=70KA/415 V AC 4-, , TM, LI IN=250A, IR=200-250A, II=1200-2500A, SIEMENS
3VL3725-2EC43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500A, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-2DK36-.... VL 250 H ICU=70KA/415 V AC 3-, IN=250A, II=2000-4000A, .. SIEMENS
3VL3725-2DK33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., STARTER COMBINATION PROTECTION MAGNETIC IN=250A, RATED CURRENT II=2000-4000A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-2DE36-.... VL 250 H ICU=70KA/415 V AC 3-, IN=250A, II=4000A, .. SIEMENS
3VL3725-2DE33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., NON-AUTOMATIC MAGNETIC IN=250A, RATED CURRENT II=3500A, SHORT-CIRCUIT II=4000A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-2DC36-.... VL 250 H ICU=70KA/415 V AC 3-, , TM, LI IN=250A, IR=200-250A, II=1200-2500A, .. SIEMENS
3VL3725-2DC33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-2CP36-0A.. . VL 250H . ICU=70KA / 415 V AC 3 , MOTOR/GENERATOR PROTECTION .. LCD ETU40M, LI IN=250A, . IR=100-250A, II=1,25TO11XIN, .. . SIEMENS
3VL3725-2CP36-.... VL 250 H ICU=70KA/415 V AC 3-, ./ .. LCD ETU40M, LI IN=250A, IR=0,4.1,0 X IN, II=1,25 11XIN, .. SIEMENS
3VL3725-2CP33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2CP33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITH SIEMENS
3VL3725-2CN46-0A.. . VL 250H . ICU=70KA / 415 V AC 4 , .. LCD ETU42, LSIG IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. N .. WITHOUT AUXILI SIEMENS
3VL3725-2CN46-.... VL 250 H ICU=70KA/415 V AC 4-, , LCD ETU42, LSIG IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3725-2CN43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2CN43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITH SIEMENS
3VL3725-2CM36-0A.. . VL 250H . ICU=70KA / 415 V AC 3 , .. LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. WITHOUT AUXILIA SIEMENS
3VL3725-2CM36-.... VL 250 H ICU=70KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3725-2CM33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2CM33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-2CL36-0A.. . VL 250H . ICU=70KA / 415 V AC 3 , .. LCD ETU42, LSIG 3/3 IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. . SIEMENS
3VL3725-2CL36-.... VL 250 H ICU=70KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3725-2CL33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2CL33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-2CJ46-0A.. . VL 250H . ICU=70KA / 415 V AC 4 , .. LCD ETU40, LI/LS/LSI IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. N . SIEMENS
3VL3725-2CJ46-.... VL 250 H ICU=70KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3725-2CJ43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2CJ43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-2CH36-0A.. . VL 250H . ICU=70KA / 415 V AC 3 , .. LCD ETU40, LI/LS/LSI IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. . SIEMENS
3VL3725-2CH36-.... VL 250 H ICU=70KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL3725-2CH33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2CH33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-2AA46-0AA0 . VL 250H ... ICU= 70 KA / 415 V AC, 4- IN= < 250 A, RATED CURRENT WITHOUT AUXILIARY RELEASE WITH SCREW CONNECTIONS CONTACT UNIT AND OVERVOLTAGE RELEASE SIEMENS
3VL3725-2AA36-0AA0 . VL 250H ... ICU= 70 KA / 415 V AC, 3- IN= < 250 A, RATED CURRENT WITHOUT AUXILIARY RELEASE WITH SCREW CONNECTIONS CONTACT UNIT AND OVERVOLTAGE RELEASE SIEMENS
3VL3725-1SS33-0A.. . VL 250N . .. R.U.S.-C.BR.C.= 40 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1SH33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1TN46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1TH46-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-1TH43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1TH43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-1TF46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1TF46-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-1TF43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1TF43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-1SS36-0A.. . VL 250N . .. R.U.S.-C.BR.C.= 40 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1SS36-.... . VL 250N . .. R.U.S.-C.BR.C.= 40 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION SIEMENS
3VL3725-1MS33-0A.. . VL 250N . .. R.U.S.-C.BR.C.= 40 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1SS33-.... . VL 250N . .. R.U.S.-C.BR.C.= 40 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITH SIEMENS
3VL3725-1SP36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1SP36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3725-1SP33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1SP33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3725-1SH36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1SH36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3725-1MH33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1SH33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-1SG36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1SG36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3725-1SG33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1SG33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-1SL36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1SL36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3725-1SL33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1SL33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3725-1SE36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1SE36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3725-1SE33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1SE33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-1SB36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1SB36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3725-1SB33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1SB33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3725-1LS36-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LS36-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LS33-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LS33-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LF46-0A.. . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LF46-.... . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LF43-0A.. . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LF43-.... . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LE36-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LA43-0A.. . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LA43-.... . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1EM46-.... . VL 250N . .. ICU= 40KA, 415V AC 4 , .. TM, LI IN= 250A, . IR= 200...250A, II= 1250...2500A, .. N (100%) SIEMENS
3VL3725-1EM43-.... . VL 250N . .. ICU= 40KA, 415V AC 4 ., LINE PROTECTION TM, LI IN= 250A, RATED CURRENT IR= 200...250A, OVERLOAD II= 1250...2500A, SHORT-CIRCUIT N PROTECTED (100%) WITH SIEMENS
3VL3725-1EJ46-.... VL 250N ICU=40KA/415 V AC 4-, , TM, LI IN=250A, IR=200-250A, II=1200-2500A, SIEMENS
3VL3725-1EJ43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500A, SHORT-CIRCUIT N NOT PROTECTED WITH SIEMENS
3VL3725-1EE46-.... VL 250N ICU=40KA/415 V AC 4-, IN=250A, II=4000A, .. SIEMENS
3VL3725-1EE43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., NON-AUTOMATIC MAGNETIC IN=250A, RATED CURRENT II=3500A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-1EC46-.... VL 250N ICU=40KA/415 V AC 4-, , TM, LI IN=250A, IR=200-250A, II=1200-2500A, SIEMENS
3VL3725-1EC43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500A, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-1DK36-.... VL 250N ICU=40KA/415 V AC 3-, IN=250A, II=2000-4000A, .. SIEMENS
3VL3725-1DK33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., STARTER COMBINATION PROTECTION MAGNETIC IN=250A, RATED CURRENT II=2000-4000A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-1DE36-.... VL 250N ICU=40KA/415 V AC 3-, IN=250A, II=4000A, .. SIEMENS
3VL3725-1DE33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., NON-AUTOMATIC MAGNETIC IN=250A, RATED CURRENT II=3500A, SHORT-CIRCUIT II=4000A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-1DC36-.... VL 250N ICU=40KA/415 V AC 3-, , TM, LI IN=250A, IR=200-250A, II=1200-2500A, .. SIEMENS
3VL3725-1DC33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500A, SHORT-CIRCUIT WITH SIEMENS
3VL3725-1CP36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 , MOTOR/GENERATOR PROTECTION .. LCD ETU40M, LI IN=250A, . IR=100-250A, II=1,25TO11XIN, .. . SIEMENS
3VL3725-1CP36-.... VL 250N ICU=40KA/415 V AC 3-, ./ .. LCD ETU40M, LI IN=250A, IR=0,4.1,0 X IN, II=1,25 11XIN, .. SIEMENS
3VL3725-1CP33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1CP33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITH SIEMENS
3VL3725-1CN46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 , .. LCD ETU42, LSIG IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. N .. WITHOUT AU SIEMENS
3VL3725-1CN46-.... VL 250N ICU=40KA/415 V AC 4-, , LCD ETU42, LSIG IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3725-1CN43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1CN43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITH SIEMENS
3VL3725-1CM36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 , .. LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. WITHOUT AUX SIEMENS
3VL3725-1TA43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-1TB46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1NB43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1CM36-.... VL 250N ICU=40KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XI SIEMENS
3VL3725-1CM33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1CM33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-1CL36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 , .. LCD ETU42, LSIG 3/3 IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. WITHOUT AUXILIARY RELEAS SIEMENS
3VL3725-1CL36-.... VL 250N ICU=40KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XI SIEMENS
3VL3725-1CL33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1CL33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-1CJ46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 , .. LCD ETU40, LI/LS/LSI IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. N WITHOUT AUXILIARY RELE SIEMENS
3VL3725-1CJ46-.... VL 250N ICU=40KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3725-1CJ43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1CJ43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-1CH36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 , .. LCD ETU40, LI/LS/LSI IN=250A, . IR=100-250A, ISD=1,5TO10XIR, II=11XIN .. . SIEMENS
3VL3725-1CH36-.... VL 250N ICU=40KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=250A, IR=100-250A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL3725-1CH33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1CH33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-1AA46-0AA0 . VL 250N . .. ICU= 40 KA / 415 V AC, 4- IN= < 250 A, RATED CURRENT WITHOUT AUXILIARY RELEASE WITH SCREW CONNECTIONS CONTACT UNIT AND OVERVOLTAGE RELEASE SIEMENS
3VL3725-1AA36-0AA0 . VL 250N . .. ICU= 40 KA / 415 V AC, 3- IN= < 250 A, RATED CURRENT WITH SCREWED UNION CONNECTION CONNECTIONS CONTACT UNIT AND SIEMENS
3VL3720-3TH43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3SS33-0A.. . VL 250L . ... R.U.S.-C.BR.C.= 100 KA, 415V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3SG33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3TF46-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-3TF43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3TF43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-3TB46-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-3TB46-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-3TB43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3TB43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-3SS36-0A.. . VL 250L . ... R.U.S.-C.BR.C.= 100 KA, 415V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-3SS36-.... . VL 250L . ... R.U.S.-C.BR.C.= 100 KA, 415V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION SIEMENS
3VL3720-3MS33-0A.. . VL 250L . ... R.U.S.-C.BR.C.= 100 KA, 415V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3SS33-.... . VL 250L . ... R.U.S.-C.BR.C.= 100 KA, 415V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITH SIEMENS
3VL3720-3SP36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-3SP36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3720-3SP33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3SP33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3720-3MH33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3MG33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3ME36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-3TH46-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-3NH43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3TH43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-3TF46-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2MH33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2SH33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3725-2SG36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-1NN46-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3725-1NN43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1NN43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3725-1NH46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2ME36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2ME36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3725-2ME33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-1NB46-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-3MG33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-3SL36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-3SE36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3720-3SE33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3SE33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-3SB36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-3LB36-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LB33-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3EM43-.... . VL 250L . ... ICU= 100KA, 415V AC 4 ., LINE PROTECTION TM, LI IN= 200A, RATED CURRENT IR= 160...200A, OVERLOAD II= 1000...2000A, SHORT-CIRCUIT N PROTECTED (100%) WITH SIEMENS
3VL3720-3EJ46-.... VL 250L ICU=100KA/415 V AC 4-, , TM, LI IN=200A, IR=160-200A, II=1000-2000A, SIEMENS
3VL3720-3EJ43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=200A, RATED CURRENT IR=160-200A, OVERLOAD II=1000-2000A, SHORT-CIRCUIT N NOT PROTECTED WITH SIEMENS
3VL3720-3EC46-.... VL 250L ICU=100KA/415 V AC 4-, , TM, LI IN=200A, IR=160-200A, II=1000-2000A, SIEMENS
3VL3720-3EC43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=200A, RATED CURRENT IR=160-200A, OVERLOAD II=1000-2000A, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-3DC36-.... VL 250L ICU=100KA/415 V AC 3-, , TM, LI IN=200A, IR=160-200A, II=1000-2000A, .. SIEMENS
3VL3720-3DC33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION TM, LI IN=200A, RATED CURRENT IR=160-200A, OVERLOAD II=1000-2000A, SHORT-CIRCUIT WITH SIEMENS
3VL3720-3CP36-0A.. . VL 250L . . ICU=100KA / 415 V AC 3 , MOTOR/GENERATOR PROTECTION .. LCD ETU40M, LI IN=200A, . IR=80-200A, II=1,25TO11XIN, .. . SIEMENS
3VL3720-3CP36-.... VL 250L ICU=100KA/415 V AC 3-, ./ .. LCD ETU40M, LI IN=200A, IR=0,4.1,0 X IN, II=1,25 11XIN, .. SIEMENS
3VL3720-3CP33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3CP33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITH SIEMENS
3VL3720-3CN46-0A.. . VL 250L . . ICU=100KA / 415 V AC 4 , .. LCD ETU42, LSIG IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. N .. WITHOUT A SIEMENS
3VL3720-3CN46-.... VL 250L ICU=100KA/415 V AC 4-, , LCD ETU42, LSIG IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3720-3CN43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3CN43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITH SIEMENS
3VL3720-3CM36-0A.. . VL 250L . . ICU=100KA / 415 V AC 3 , .. LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. WITHOUT AU SIEMENS
3VL3720-3CM36-.... VL 250L ICU=100KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11 SIEMENS
3VL3720-3CM33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3CM33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-3CL36-0A.. . VL 250L . . ICU=100KA / 415 V AC 3 , .. LCD ETU42, LSIG 3/3 IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. WITHOUT AUXILIARY RELEA SIEMENS
3VL3720-3CL36-.... VL 250L ICU=100KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11 SIEMENS
3VL3720-3CL33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3CL33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-3CJ46-0A.. . VL 250L . . ICU=100KA / 415 V AC 4 , .. LCD ETU40, LI/LS/LSI IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. N WITHOUT AUXILIARY REL SIEMENS
3VL3720-3CJ46-.... VL 250L ICU=100KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3720-3CJ43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3CJ43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-3CH36-0A.. . VL 250L . . ICU=100KA / 415 V AC 3 , .. LCD ETU40, LI/LS/LSI IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. . SIEMENS
3VL3720-3CH36-.... VL 250L ICU=100KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL3720-3CH33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3CH33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-2SS33-0A.. . VL 250H ... R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3SB36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3720-3SB33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3LS36-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LS36-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LS33-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LS33-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LF46-0A.. . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LF46-.... . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LF43-0A.. . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LF43-.... . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LE36-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LE36-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LE33-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LE33-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LB36-0A.. . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2TN46-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2TN46-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-2TN43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2TN43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-2TH46-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2TH46-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-2TH43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2TB46-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2TB46-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-2TB43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2TB43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-2SS36-0A.. . VL 250H ... R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2SS36-.... . VL 250H ... R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION SIEMENS
3VL3720-2MS33-0A.. . VL 250H ... R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2SS33-.... . VL 250H ... R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITH SIEMENS
3VL3720-2SP36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2SP36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3720-2SP33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2SP33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3720-2MH33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2SL36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2SL36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3720-2SL33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2SL33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3720-2SE36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2SE36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3720-2SE33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2SE33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-2SB36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2SB36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3720-2SB33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2SB33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3720-2LS36-0A.. . VL 250H .. ICU= 70KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LS36-.... . VL 250H .. ICU= 70KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION II= 1.25 TO 11 X IN, MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LS33-0A.. . VL 250H .. ICU= 70KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LS33-.... . VL 250H . ICU= 70KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION II= 1.25 TO 11 X IN, W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LB36-0A.. . VL 250H .. ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LB36-.... . VL 250H .. ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LB33-0A.. . VL 250H .. ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LB33-.... . VL 250H .. ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LA46-0A.. . VL 250H .. ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LA46-.... . VL 250H .. ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LA43-0A.. . VL 250H .. ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LA43-.... . VL 250H .. ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2EM46-.... . VL 250H . ICU= 70KA, 415V AC 4 , .. TM, LI IN= 200A, . IR= 160...200A, II= 1000...2000A, .. N (100%) SIEMENS
3VL3720-2EM43-.... . VL 250H ... ICU= 70KA, 415V AC 4 ., LINE PROTECTION TM, LI IN= 200A, RATED CURRENT IR= 160...200A, OVERLOAD II= 1000...2000A, SHORT-CIRCUIT N PROTECTED (100%) WITH SIEMENS
3VL3720-2EJ46-.... VL 250 H ICU=70KA/415 V AC 4-, , TM, LI IN=200A, IR=160-200A, II=1000-2000A, SIEMENS
3VL3720-2EJ43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=200A, RATED CURRENT IR=160-200A, OVERLOAD II=1000-2000A, SHORT-CIRCUIT N NOT PROTECTED WITH SIEMENS
3VL3720-2EC46-.... VL 250 H ICU=70KA/415 V AC 4-, , TM, LI IN=200A, IR=160-200A, II=1000-2000A, SIEMENS
3VL3720-2EC43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=200A, RATED CURRENT IR=160-200A, OVERLOAD II=1000-2000A, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-2DC36-.... VL 250 H ICU=70KA/415 V AC 3-, , TM, LI IN=200A, IR=160-200A, II=1000-2000A, .. SIEMENS
3VL3720-2DC33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION TM, LI IN=200A, RATED CURRENT IR=160-200A, OVERLOAD II=1000-2000A, SHORT-CIRCUIT WITH SIEMENS
3VL3720-2CP36-0A.. . VL 250H . ICU=70KA / 415 V AC 3 , MOTOR/GENERATOR PROTECTION .. LCD ETU40M, LI IN=200A, . IR=80-200A, II=1,25TO11XIN, .. . SIEMENS
3VL3720-2CP36-.... VL 250 H ICU=70KA/415 V AC 3-, ./ .. LCD ETU40M, LI IN=200A, IR=0,4.1,0 X IN, II=1,25 11XIN, .. SIEMENS
3VL3720-2CP33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2CP33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITH SIEMENS
3VL3720-2CN46-0A.. . VL 250H . ICU=70KA / 415 V AC 4 , .. LCD ETU42, LSIG IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. N .. WITHOUT AUXILIA SIEMENS
3VL3720-2CN46-.... VL 250 H ICU=70KA/415 V AC 4-, , LCD ETU42, LSIG IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3720-2CN43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2CN43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITH SIEMENS
3VL3720-2CM36-0A.. . VL 250H . ICU=70KA / 415 V AC 3 , .. LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. WITHOUT AUXILIAR SIEMENS
3VL3720-2CM36-.... VL 250 H ICU=70KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN . SIEMENS
3VL3720-2CM33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2CM33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-2CL36-0A.. . VL 250H . ICU=70KA / 415 V AC 3 , .. LCD ETU42, LSIG 3/3 IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. . SIEMENS
3VL3720-2CL36-.... VL 250 H ICU=70KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN . SIEMENS
3VL3720-2CL33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2CL33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-2CJ46-0A.. . VL 250H . ICU=70KA / 415 V AC 4 , .. LCD ETU40, LI/LS/LSI IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. N . SIEMENS
3VL3720-2CJ46-.... VL 250 H ICU=70KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3720-2CJ43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2CJ43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-2CH36-0A.. . VL 250H . ICU=70KA / 415 V AC 3 , .. LCD ETU40, LI/LS/LSI IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. . SIEMENS
3VL3720-2CH36-.... VL 250 H ICU=70KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL3720-2CH33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2CH33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-1SS33-0A.. . VL 250N . .. R.U.S.-C.BR.C.= 40 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1TN46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-1TN46-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-1TN43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1TN43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-1TH46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-1TH46-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-1TH43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1TH43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-1SH33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2MH36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2MH36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3720-2SH33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2MH33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-2MG36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2MG36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3720-2MG33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2MG33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-2LF46-0A.. . VL 250H . ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LF46-.... . VL 250H . ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LF43-0A.. . VL 250H . ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LF43-.... . VL 250H . ICU= 70KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LE36-0A.. . VL 250H . ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LE36-.... . VL 250H .. ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LE33-0A.. . VL 250H .. ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-2LE33-.... . VL 250H .. ICU= 70KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1SG36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-1SG36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3720-1SG33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1SG33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-1SE36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-1SE36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3720-1SE33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1SE33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-1SB36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-1SB36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3720-1SB33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1SB33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3720-1TF46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-1TF46-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-1TF43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1TF43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-1TB46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-1TB46-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-1TB43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1TB43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-1SS36-0A.. . VL 250N . .. R.U.S.-C.BR.C.= 40 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-1SH36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3720-1MH33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1SH33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-1CM36-.... VL 250N ICU=40KA/415 V AC 3-, , LCD ETU42, LSIG 3 /4 IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3720-1CM33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1CM33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-1CL36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 , .. LCD ETU42, LSIG 3/3 IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. . SIEMENS
3VL3720-1CL36-.... VL 250N ICU=40KA/415 V AC 3-, , LCD ETU42, LSIG 3 /3 IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3720-1CL33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1CL33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU42, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-1CJ46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 , .. LCD ETU40, LI/LS/LSI IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. N WITHOUT AUXILIARY RELEA SIEMENS
3VL3720-1CJ46-.... VL 250N ICU=40KA/415 V AC 4-, , LCD ETU40, LI/LS/LSI IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3720-1CJ43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1CJ43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-1CH36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 , .. LCD ETU40, LI/LS/LSI IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. . SIEMENS
3VL3720-1CH36-.... VL 250N ICU=40KA/415 V AC 3-, , LCD ETU40, LI/LS/LSI IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN .. SIEMENS
3VL3720-1CH33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1CH33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION LCD ETU40, LI/LS/LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3125-3KN30-.... . VL 250 UL; FG (CAT NO. LFX3B250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 1250...2500A SHORT-CIRCUIT PROTECTION IR= 250A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-3KE30-.... . VL 250 UL; FG (CAT NO. LFS3S250L) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE SWITCH) MAGNETIC TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 3500A SHORT-CIRCUIT PROTECTION ISOLATING . W/O CONNECTION SIEMENS
3VL3125-3JM30-0A.. . VL 250 UL; FG (CAT NO. LFX3E250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-3JM30-.... . VL 250 UL; FG (CAT NO. LFX3E250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-3JH30-0A.. . VL 250 UL; FG (CAT NO. LFX3D250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-3JH30-.... . VL 250 UL; FG (CAT NO. LFX3D250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-3GH30-0A.. . VL 250 UL; FG (CAT NO. LFX3U250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-3GH30-.... . VL 250 UL; FG (CAT NO. LFX3U250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-3GE30-0A.. . VL 250 UL; FG (CAT NO. LFX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-3GE30-.... . VL 250 UL; FG (CAT NO. LFX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-3GD30-0A.. . VL 250 UL; FG (CAT NO. LFX3X250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-3GD30-.... . VL 250 UL; FG (CAT NO. LFX3X250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-3GB30-0A.. . VL 250 UL; FG (CAT NO. LFX3N250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-3GB30-.... . VL 250 UL; FG (CAT NO. LFX3N250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-2KN33-.... . VL 250 UL; FG (CAT NO. HFX3B250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 1250...2500A SHORT-CIRCUIT PROTECTION IR= 250A .. F. PLANT PROTECTION WITH CONNECTION TERMINALS ON LINE AND LOAD SIDE SIEMENS
3VL3125-2KN32-.... . VL 250 UL; FG (CAT NO. HFX3B250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 1250...2500A SHORT-CIRCUIT PROTECTION IR= 250A .. F. PLANT PROTECTION WITH CONNECTION TERMINALS ON LOAD SIDE SIEMENS
3VL3125-2KN31-.... . VL 250 UL; FG (CAT NO. HFX3B250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 1250...2500A SHORT-CIRCUIT PROTECTION IR= 250A .. F. PLANT PROTECTION WITH CONNECTION TERMINALS ON LINE SIDE SIEMENS
3VL3125-2KN30-.... . VL 250 UL; FG (CAT NO. HFX3B250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 1250...2500A SHORT-CIRCUIT PROTECTION IR= 250A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-2KL30-.... . VL 250 UL; FG (CAT NO. HFM3H250L) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOTOR STARTER PROTECTOR) MAGNETIC TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 1750..3500A SHORT-CIRCUIT PROTECTION STARTER COMBINATION W/O CONNECTION SIEMENS
3VL3125-2KK30-.... . VL 250 UL; FG (CAT NO. HFM3M250L) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOTOR STARTER PROTECTOR) MAGNETIC TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 1000..2000A SHORT-CIRCUIT PROTECTION STARTER COMBINATION W/O CONNECTION SIEMENS
3VL3125-2KJ30-.... . VL 250 UL; FG (CAT NO. HFM3L250L) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOTOR STARTER PROTECTOR) MAGNETIC TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 600..1200A SHORT-CIRCUIT PROTECTION STARTER COMBINATION W/O CONNECTION SIEMENS
3VL3125-2KE30-.... . VL 250 UL; FG (CAT NO. HFS3S250L) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE SWITCH) MAGNETIC TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 3500A SHORT-CIRCUIT PROTECTION ISOLATING . W/O CONNECTION SIEMENS
3VL3125-2JM30-0A.. . VL 250 UL; FG (CAT NO. HFX3E250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-2JM30-.... . VL 250 UL; FG (CAT NO. HFX3E250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-2JH30-0A.. . VL 250 UL; FG (CAT NO. HFX3D250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-2JH30-.... . VL 250 UL; FG (CAT NO. HFX3D250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-2GH30-0A.. . VL 250 UL; FG (CAT NO. NFX3U250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-2GH30-.... . VL 250 UL; FG (CAT NO. NFX3U250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-2GE33-.... . VL 250 UL; FG (CAT NO. HFX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION WITH CONNECTION TERMINALS ON LINE AND LOAD SIDE SIEMENS
3VL3720-1LS36-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W. SCREW TERMINAL W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LS36-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W. SCREW TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LS33-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W. SCREW TERMINAL W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LS33-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., MOTOR PROTECTION ETU30M, LI IR= 80...200A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W. SCREW TERMINAL W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LB36-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LB33-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LB33-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LA46-0A.. . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LA46-.... . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LA43-0A.. . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LA43-.... . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1EM46-.... . VL 250N . .. ICU= 40KA, 415V AC 4 , .. TM, LI IN= 200A, . IR= 160...200A, II= 1000...2000A, .. N (100%) SIEMENS
3VL3720-1EM43-.... . VL 250N . .. ICU= 40KA, 415V AC 4 ., LINE PROTECTION TM, LI IN= 200A, RATED CURRENT IR= 160...200A, OVERLOAD II= 1000...2000A, SHORT-CIRCUIT N PROTECTED (100%) WITH SIEMENS
3VL3720-1EJ46-.... VL 250N ICU=40KA/415 V AC 4-, , TM, LI IN=200A, IR=160-200A, II=1000-2000A, SIEMENS
3VL3720-1EJ43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=200A, RATED CURRENT IR=160-200A, OVERLOAD II=1000-2000A, SHORT-CIRCUIT N NOT PROTECTED WITH SIEMENS
3VL3720-1EC46-.... VL 250N ICU=40KA/415 V AC 4-, , TM, LI IN=200A, IR=160-200A, II=1000-2000A, SIEMENS
3VL3720-1EC43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION TM, LI IN=200A, RATED CURRENT IR=160-200A, OVERLOAD II=1000-2000A, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-1DC36-.... VL 250N ICU=40KA/415 V AC 3-, , TM, LI IN=200A, IR=160-200A, II=1000-2000A, .. SIEMENS
3VL3720-1DC33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION TM, LI IN=200A, RATED CURRENT IR=160-200A, OVERLOAD II=1000-2000A, SHORT-CIRCUIT WITH SIEMENS
3VL3720-1CP36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 , MOTOR/GENERATOR PROTECTION .. LCD ETU40M, LI IN=200A, . IR=80-200A, II=1,25TO11XIN, .. . SIEMENS
3VL3720-1CP36-.... VL 250N ICU=40KA/415 V AC 3-, ./ .. LCD ETU40M, LI IN=200A, IR=0,4.1,0 X IN, II=1,25 11XIN, .. SIEMENS
3VL3720-1CP33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1CP33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/GENERATOR PROTECTION LCD ETU40M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITH SIEMENS
3VL3720-1CN46-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 , .. LCD ETU42, LSIG IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. N .. WITHOUT AUX SIEMENS
3VL3720-1CN46-.... VL 250N ICU=40KA/415 V AC 4-, , LCD ETU42, LSIG IN=200A, IR=80-200A, ISD=1,5 10XIR, II=11XIN SIEMENS
3VL3720-1CN43-0A.. . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1CN43-.... . VL 250N . .. ICU=40KA / 415 V AC 4 ., LINE PROTECTION LCD ETU42, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITH SIEMENS
3VL3720-1CM36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 , .. LCD ETU42, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, . IR=80-200A, ISD=1,5TO10XIR, II=11XIN .. WITHOUT AUXI SIEMENS
3VL3125-2GE32-.... . VL 250 UL; FG (CAT NO. HFX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION WITH CONNECTION TERMINALS ON LOAD SIDE SIEMENS
3VL3125-2GE31-.... . VL 250 UL; FG (CAT NO. HFX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION WITH CONNECTION TERMINALS ON LINE SIDE SIEMENS
3VL3125-2GE30-0A.. . VL 250 UL; FG (CAT NO. HFX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-2GE30-.... . VL 250 UL; FG (CAT NO. HFX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-2GD30-0A.. . VL 250 UL; FG (CAT NO. HFX3X250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-2GD30-.... . VL 250 UL; FG (CAT NO. HFX3X250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-2GB30-0A.. . VL 250 UL; FG (CAT NO. NFX3N250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-2GB30-.... . VL 250 UL; FG (CAT NO. NFX3N250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-1KN30-.... . VL 250 UL; FG (CAT NO. NFX3B250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 250A, RATED CURRENT II= 1250...2500A SHORT-CIRCUIT PROTECTION IR= 250A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-1JM30-0A.. . VL 250 UL; FG (CAT NO. NFX3E250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-1JM30-.... . VL 250 UL; FG (CAT NO. NFX3E250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-1JH30-0A.. . VL 250 UL; FG (CAT NO. NFX3D250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-1JH30-.... . VL 250 UL; FG (CAT NO. NFX3D250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-1GH30-0A.. . VL 250 UL; FG (CAT NO. NFX3U250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-1GH30-.... . VL 250 UL; FG (CAT NO. NFX3U250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-1GE30-0A.. . VL 250 UL; FG (CAT NO. NFX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-1GE30-.... . VL 250 UL; FG (CAT NO. NFX3P250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-1GD30-0A.. . VL 250 UL; FG (CAT NO. NFX3X250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-1GD30-.... . VL 250 UL; FG (CAT NO. NFX3X250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3125-1GB30-0A.. . VL 250 UL; FG (CAT NO. NFX3N250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3125-1GB30-.... . VL 250 UL; FG (CAT NO. NFX3N250) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 250A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3122-3KN30-.... . VL 250 UL; FG (CAT NO. LFX3B225) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 225A, RATED CURRENT II= 1250...2500A SHORT-CIRCUIT PROTECTION IR= 225A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3122-2KN30-.... . VL 250 UL; FG (CAT NO. HFX3B225) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 225A, RATED CURRENT II= 1250...2500A SHORT-CIRCUIT PROTECTION IR= 225A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3122-1KN30-.... . VL 250 UL; FG (CAT NO. NFX3B225) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 225A, RATED CURRENT II= 1250...2500A SHORT-CIRCUIT PROTECTION IR= 225A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3120-3KN30-.... . VL 250 UL; FG (CAT NO. LFX3B200) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 200A, RATED CURRENT II= 1000...2000A SHORT-CIRCUIT PROTECTION IR= 200A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3120-2KN33-.... . VL 250 UL; FG (CAT NO. HFX3B200) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 200A, RATED CURRENT II= 1000...2000A SHORT-CIRCUIT PROTECTION IR= 200A .. F. PLANT PROTECTION WITH CONNECTION TERMINALS ON LINE AND LOAD SIDE SIEMENS
3VL3120-2KN32-.... . VL 250 UL; FG (CAT NO. HFX3B200) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 200A, RATED CURRENT II= 1000...2000A SHORT-CIRCUIT PROTECTION IR= 200A .. F. PLANT PROTECTION WITH CONNECTION TERMINALS ON LOAD SIDE SIEMENS
3VL3120-2KN31-.... . VL 250 UL; FG (CAT NO. HFX3B200) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 200A, RATED CURRENT II= 1000...2000A SHORT-CIRCUIT PROTECTION IR= 200A .. F. PLANT PROTECTION WITH CONNECTION TERMINALS ON LINE SIDE SIEMENS
3VL3120-2KN30-.... . VL 250 UL; FG (CAT NO. HFX3B200) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 200A, RATED CURRENT II= 1000...2000A SHORT-CIRCUIT PROTECTION IR= 200A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3120-1KN30-.... . VL 250 UL; FG (CAT NO. NFX3B200) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 200A, RATED CURRENT II= 1000...2000A SHORT-CIRCUIT PROTECTION IR= 200A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3117-3KN30-.... . VL 250 UL; FG (CAT NO. LFX3B170) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 170A, RATED CURRENT II= 1000...2000A SHORT-CIRCUIT PROTECTION IR= 175A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3117-2KN30-.... . VL 250 UL; FG (CAT NO. HFX3B170) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 170A, RATED CURRENT II= 1000...2000A SHORT-CIRCUIT PROTECTION IR= 175A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3117-1KN30-.... . VL 250 UL; FG (CAT NO. NFX3B170) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 170A, RATED CURRENT II= 1000...2000A SHORT-CIRCUIT PROTECTION IR= 175A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-3KN30-.... . VL 250 UL; FG (CAT NO. LFX3B150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 150A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 150A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-3JM30-0A.. . VL 250 UL; FG (CAT NO. LFX3E150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-3JM30-.... . VL 250 UL; FG (CAT NO. LFX3E150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-3JH30-0A.. . VL 250 UL; FG (CAT NO. LFX3D150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-3JH30-.... . VL 250 UL; FG (CAT NO. LFX3D150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-3GH30-0A.. . VL 250 UL; FG (CAT NO. LFX3U150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-3GH30-.... . VL 250 UL; FG (CAT NO. LFX3U150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-2JH30-0A.. . VL 250 UL; FG (CAT NO. HFX3D150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-2JH30-.... . VL 250 UL; FG (CAT NO. HFX3D150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-2GH30-0A.. . VL 250 UL; FG (CAT NO. HFX3U150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-2GH30-.... . VL 250 UL; FG (CAT NO. HFX3U150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-2GE30-0A.. . VL 250 UL; FG (CAT NO. HFX3P150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-2GE30-.... . VL 250 UL; FG (CAT NO. HFX3P150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-2GD30-0A.. . VL 250 UL; FG (CAT NO. HFX3X150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-2GD30-.... . VL 250 UL; FG (CAT NO. HFX3X150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-2GB30-0A.. . VL 250 UL; FG (CAT NO. HFX3N150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-2GB30-.... . VL 250 UL; FG (CAT NO. HFX3N150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-1KN30-.... . VL 250 UL; FG (CAT NO. NFX3B150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 150A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 150A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-1JM30-0A.. . VL 250 UL; FG (CAT NO. NFX3E150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-1JM30-.... . VL 250 UL; FG (CAT NO. NFX3E150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-1JH30-0A.. . VL 250 UL; FG (CAT NO. NFX3D150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-1JH30-.... . VL 250 UL; FG (CAT NO. NFX3D150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-1GH30-0A.. . VL 250 UL; FG (CAT NO. NFX3U150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-1GH30-.... . VL 250 UL; FG (CAT NO. NFX3U150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-1GE30-0A.. . VL 250 UL; FG (CAT NO. NFX3P150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-1GE30-.... . VL 250 UL; FG (CAT NO. NFX3P150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-1GD30-0A.. . VL 250 UL; FG (CAT NO. NFX3X150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-1GD30-.... . VL 250 UL; FG (CAT NO. NFX3X150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-1GB30-0A.. . VL 250 UL; FG (CAT NO. NFX3N150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-1GB30-.... . VL 250 UL; FG (CAT NO. NFX3N150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3112-3KN30-.... . VL 250 UL; FG (CAT NO. LFX3B125) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 125A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 125A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-3JH30-0A.. . VL 250 UL; FG (CAT NO. LFX3D100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-3JH30-.... . VL 250 UL; FG (CAT NO. LFX3D100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-3GH30-0A.. . VL 250 UL; FG (CAT NO. LFX3U100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-3GH30-.... . VL 250 UL; FG (CAT NO. LFX3U100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-3GE30-0A.. . VL 250 UL; FG (CAT NO. LFX3P100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-3GE30-.... . VL 250 UL; FG (CAT NO. LFX3P100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-3GD30-0A.. . VL 250 UL; FG (CAT NO. LFX3X100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-3GD30-.... . VL 250 UL; FG (CAT NO. LFX3X100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-3GB30-0A.. . VL 250 UL; FG (CAT NO. LFX3N100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-3GB30-.... . VL 250 UL; FG (CAT NO. LFX3N100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-2KN30-.... . VL 250 UL; FG (CAT NO. HFX3B100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 100A, RATED CURRENT II= 625...1250A SHORT-CIRCUIT PROTECTION IR= 100A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-2JM30-0A.. . VL 250 UL; FG (CAT NO. HFX3E100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-2JM30-.... . VL 250 UL; FG (CAT NO. HFX3E100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-2JH30-0A.. . VL 250 UL; FG (CAT NO. HFX3D100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-2JH30-.... . VL 250 UL; FG (CAT NO. HFX3D100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-2GH30-0A.. . VL 250 UL; FG (CAT NO. HFX3U100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-2GH30-.... . VL 250 UL; FG (CAT NO. HFX3U100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-2GE30-0A.. . VL 250 UL; FG (CAT NO. HFX3P100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-2GE30-.... . VL 250 UL; FG (CAT NO. HFX3P100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-2GD30-0A.. . VL 250 UL; FG (CAT NO. HFX3X100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-2GD30-.... . VL 250 UL; FG (CAT NO. HFX3X100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-2GB30-0A.. . VL 250 UL; FG (CAT NO. HFX3N100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-2GB30-.... . VL 250 UL; FG (CAT NO. HFX3N100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-1KN30-.... . VL 250 UL; FG (CAT NO. NFX3B100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 100A, RATED CURRENT II= 625...1250A SHORT-CIRCUIT PROTECTION IR= 100A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-1JM30-0A.. . VL 250 UL; FG (CAT NO. NFX3E100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-1JM30-.... . VL 250 UL; FG (CAT NO. NFX3E100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-1JH30-0A.. . VL 250 UL; FG (CAT NO. NFX3D100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-1JH30-.... . VL 250 UL; FG (CAT NO. NFX3D100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-1GH30-0A.. . VL 250 UL; FG (CAT NO. NFX3U100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-1GH30-.... . VL 250 UL; FG (CAT NO. NFX3U100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-1GE30-0A.. . VL 250 UL; FG (CAT NO. NFX3P100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= < 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-1GE30-.... . VL 250 UL; FG (CAT NO. NFX3P100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= < 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-1GD30-0A.. . VL 250 UL; FG (CAT NO. NFX3X100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-1GD30-.... . VL 250 UL; FG (CAT NO. NFX3X100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-1GB30-0A.. . VL 250 UL; FG (CAT NO. NFX3N100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 100A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3112-2KN30-.... . VL 250 UL; FG (CAT NO. HFX3B125) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 125A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 125A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3112-1KN30-.... . VL 250 UL; FG (CAT NO. NFX3B125) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 125A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 125A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3111-3KN30-.... . VL 250 UL; FG (CAT NO. LFX3B110) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 110A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 110A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3111-2KN30-.... . VL 250 UL; FG (CAT NO. HFX3B110) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 110A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 110A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-3GE30-0A.. . VL 250 UL; FG (CAT NO. LFX3P150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-3GE30-.... . VL 250 UL; FG (CAT NO. LFX3P150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-3GD30-0A.. . VL 250 UL; FG (CAT NO. LFX3X150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-3GD30-.... . VL 250 UL; FG (CAT NO. LFX3X150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-3GB30-0A.. . VL 250 UL; FG (CAT NO. LFX3N150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-3GB30-.... . VL 250 UL; FG (CAT NO. LFX3N150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) ETU, LI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-2KN30-.... . VL 250 UL; FG (CAT NO. HFX3B150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 150A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 150A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3115-2JM30-0A.. . VL 250 UL; FG (CAT NO. HFX3E150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3115-2JM30-.... . VL 250 UL; FG (CAT NO. HFX3E150) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 ... 3-, NEMA RATING 65KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3725-2MP36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3725-2MP33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2MP33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3725-2SF36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2ML36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3725-2ML33-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3725-2ML33-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3725-2MH36-0A.. . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3725-2MH36-.... . VL 250H ... ICU=70KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3725-1LE36-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LE33-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LE33-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LF46-0A.. . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LF46-.... . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LF43-0A.. . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LF43-.... . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LE36-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LE36-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LE33-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LE33-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU20, LSI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-1LB36-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LB36-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LB36-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LB33-0A.. . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LB33-.... . VL 250N . .. ICU= 55KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LA46-0A.. . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3725-1LA46-.... . VL 250N . .. ICU= 55KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3ML36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3720-3ML33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3ML33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3720-3MH36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-3MH36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3720-3SH33-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3MH33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SIEMENS
3VL3720-3MG36-0A.. . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-3MG36-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT SIEMENS
3VL3720-2NH43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3111-1KN30-.... . VL 250 UL; FG (CAT NO. NFX3B110) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . .. 3-, NEMA RATING 35KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 110A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 110A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-3KN30-.... . VL 250 UL; FG (CAT NO. LFX3B100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) TM, LI TU= 40 DEGR. CELSIUS IN= < 100A, RATED CURRENT II= 625...1250A SHORT-CIRCUIT PROTECTION IR= 100A .. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3110-3JM30-0A.. . VL 250 UL; FG (CAT NO. LFX3E100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION W/O AUX. RELEASE SIEMENS
3VL3110-3JM30-.... . VL 250 UL; FG (CAT NO. LFX3E100) NON-INTERCHANGEABLE FRAME W. APPROBATION . TO UL489 . ... 3-, NEMA RATING 100KA/480V, (MOLDED CASE . ) LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 .S/4 CABLES IN= 100A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100 A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION SIEMENS
3VL3720-2NF46-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-2NF46-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-2NF43-0A.. . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-2NF43-.... . VL 250H ... ICU=70KA / 415 V AC 4 ., LINE PROTECTION ETU20, LSI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-3MB33-.... . VL 250L . ... ICU=100KA / 415 V AC 3 ., LINE PROTECTION ETU10, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3720-3TN46-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-3TN46-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED SIEMENS
3VL3720-3TN43-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-3TN43-.... . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU12, LIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT N PROTECTED WITH SIEMENS
3VL3720-3TH46-0A.. . VL 250L . ... ICU=100KA / 415 V AC 4 ., LINE PROTECTION ETU22, LSIG IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-3LB33-.... . VL 250L . ... ICU= 100KA, 415V AC 3-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LA46-0A.. . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LA46-.... . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LA43-0A.. . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3LA43-.... . VL 250L . ... ICU= 100KA, 415V AC 4-., PLANT PROTECTION ETU10, LI IN= 200A, RATED CURRENT IR= 80...200A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL LRS, DNV AND GL SIEMENS
3VL3720-3EM46-.... . VL 250L . . ICU= 100KA, 415V AC 4 , .. TM, LI IN= 200A, . IR= 160...200A, II= 1000...2000A, .. N (100%) SIEMENS
3VL3720-1SS36-.... . VL 250N . .. R.U.S.-C.BR.C.= 40 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION SIEMENS
3VL3720-1MS33-0A.. . VL 250N . .. R.U.S.-C.BR.C.= 40 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1SS33-.... . VL 250N . .. R.U.S.-C.BR.C.= 40 KA, 415 V AC 3-, MOTOR PROTECTION ETU30M, LI IN=200A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITH SIEMENS
3VL3720-1SP36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-1SP36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3720-1SP33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1SP33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., MOTOR/ GENERATOR PROTECTION ETU10M, LI IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3720-1SL36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3720-1SL36-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT SIEMENS
3VL3720-1SL33-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH SIEMENS
3VL3720-1SL33-.... . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU12, LIG 3.S/3WIRES IN=200A, RATED CURRENT IR=80-200A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITH SIEMENS
3VL3720-1SH36-0A.. . VL 250N . .. ICU=40KA / 415 V AC 3 ., LINE PROTECTION ETU22, LSIG 3.S/4WIRES WITH PIGTAIL IN=200A, RATED CURRENT IR=80-200A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE SIEMENS
3VL3110-1GB30-.... LEISTUNGSSCHALTER VL 250 UL; TYP FG (CAT NO. NFX3N100) NON-INTERCHANGEABLE FRAME M. APPROBATION CIRCUIT-BREAKER NACH UL489 STANDARD SCHALTVERMOEGEN 3POLIG, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) UEBERSTROMAUSLOESER ETU, LI TU= 40GRAD CELSIUS IN= 100A, BEMESSUNGSSTROM II= 1,25 BIS 11 X IN, KURZSCHLUSS-SCHUTZ IR= 40-100A UEBERSTROMAUSL. FUER ANLAGENSCHUTZ OHNE ANSCHLUSSZUBEHOER - 3VL31101GB30.... Siemens

1 - 770 770
 | . | 1 | . |  .